A case of delayed embolization of Amplatzer septal occluder, occurring at 2 weeks postim plantation in a 10-year-old girl with an oval-shaped secundum atrial septal defect is reported. The structurally intact device dislodged into the left atrium owing to reversal of transatrial pressure gradients and embolized to the left ventricular outflow tract from where it was retrieved surgically.
Get full access to this article
View all access options for this article.
References
1.
Sharafuddin MJ, Gu X., Titus JL, et al: Transvenous closure of secundum atrial septal defects. Preliminary results with a new self-expanding nitinol prosthesis in a swine model. Circulation95:2162-2168, 1997.
2.
Masura J., Gavora P., Formanek A., et al: Transcatheter closure of secundum atrial septal defects using the new self-centering Amplatzer septal occluder: Initial human experience . Cathet Cardiovasc Diagn42:388-393, 1997.
3.
Chan KC, Godman MJ, Walsh K., et al: Transcatheter closure of atrial septal defect and interatrial communications with a new self-expanding nitinol double-disc device (Amplatzer septal occluder): Multicentre UK experience. Heart82:300-306, 1999.
4.
Arora R., Kalra GS, Singh S., et al: Transcatheter closure of atrial septal defect using self-expandable septal occluder. Indian Heart J51:289-293, 1999.
5.
Berger F., Vogel M., Alexi-Meskishvili V., et al: Comparison of results and complications of surgical and Amplatzer device closure of atrial septal defects. J Thorac Cardiovasc Surg118:674-678, 1999.
6.
Godart F., Rey C., Francart C., et al: Experience in one centre using the buttoned device for occlusion of atrial septal defect: Comparison with the Amplatzer septal occluder. Cardiol Young10:527-533, 2000.
7.
Agarwal SK, Ghosh PK, Mittal PK: Failure of devices used for closure of atrial septal defects: Mechanisms and management. J Thorac Cardiovasc Surg112:21-26, 1996.
8.
Lloyd TR, Beckman RH: Transcatheter closure of atrial septal defect and patent ductus arteriosus . In: Textbook of Interventional Cardiology, ed. 2, ed. by Topol EJ.Philadelphia: WB Saunders, 1994, pp 1298-1311.
9.
Dhillon R., Thanopoulos B., Tsaousis G., et al: Transcatheter closure of atrial septal defects in adults with the Amplatzer septal occluder. Heart82:559-562, 1999.
10.
Taeed R., Shim D., Kimball TR, et al: One-year follow-up of the Amplatzer device to close atrial septal defects. Am J Cardiol87:116-118, 2001.
11.
Graesser EJ , Cozzarelli FA: Shape-memory alloys as new materials for aseismic isolation. J Eng Mech ASCE117:2590-2608, 1991.
12.
Paine JS, Rogers CA: Shape-memory alloys for damage-resistant composite structures. Int Soc Optical Eng2427:358-371, 1995.