Sentinel node biopsy has become the standard method for lymphatic staging in early-stage breast cancer and melanomas. The most commonly used technique uses both a radioactive tracer as well as blue dye, usually isosulfan blue. In this report, we discuss two episodes of anaphylaxis to isosulfan blue during lymphatic mapping, occurring 12 years and 3339 lymphatic mapping cases after adoption of the technique, and discuss management issues raised by these events.
CabanasR.M.An approach for the treatment of penile cancer.Cancer1977; 39: 456–66.
3.
MortonD.L., WenD.R., WongJ.H.Technical details of intraoperative lymphatic mapping for early stage melanoma.Arch Surg1992; 127: 392–9.
4.
GuilianoA.E., JonesR.C., BrennanM.Sentinel lymphadenectomy in breast cancer.J Clin Oncol1997; 15: 2345.
5.
AlboD., WayneJ.D., HuntK.K.Anaphylactic reactions to isosulfan blue dye during sentinel lymph node biopsy for breast cancer.Am J Surg2001; 182: 393–8.
6.
EfronP., KnudsenE., HirshornS.Anaphylactic reaction to isosulfan blue dye used for sentinel node biopsy: case report and literature review.Breast J2002; 8: 396–9.
7.
DewachterP., Mounton-FaivreC., TrechotP.Severe anaphylactic shock with methylene blue instillation.Anesth Analg2005; 101: 149–50.
8.
KuererH.M., WayneJ.D., RossM.I.Anaphylaxis during breast cancer lymphatic mapping.Surgery2001; 129: 119–20.
9.
KomenakaI.K., BauerV.P., SchnabelF.R.Allergic reactions to isosulfan blue in sentinel node mapping.Breast J2005; 11: 70–2.
10.
MontgomeryL.L., ThorneA.C., Van ZeeK.J.Isosulfan blue dye reactions during sentinel lymph node mapping for breast cancer.Anesth Analg2002; 95: 385–8.
11.
LyewM.A., GamblinT.C., AyoubM.Systemic anaphylaxis associated with intramammary isosulfan blue injection used for sentinel node detection under general anesthesia.Anesthesiology2000; 93: 1145–6.
RautC.P., HuntK.K., AkinsJ.S.Incidence of anaphylactoid reactions to isosulfan blue dye during breast carcinoma lymphatic mapping in patients treated with preoperative prophylaxis.Cancer2005; 104: 692–9.
14.
ThevarajahS., HustonT.L., SimmonsR.M.A comparison of the adverse reactions associated with isosulfan blue versus methylene blue dye in sentinel lymph node biopsy for breast cancer.Am J Surg2005; 189: 236–9.
15.
WilkeL.G., McCallL.M., PostherK.E.Surgical complications associated with sentinel lymph node biopsy: results from a prospective international cooperative group trial.Ann Surg Oncol2006; 13: 491–500.
16.
ZakariaS., HoskinT., DegnimA.C.Safety of methylene blue dye for lymphatic mapping in breast cancer. Poster #P195.Ann Surg Oncol2007; 14(Suppl): S-90.
17.
EldrageelyK., VargasM.P., KhalkhaliI.Sentinel lymph node mapping of breast cancer.Am J Surg2004; 70: 872–5.
18.
BlessingW.D., StolierA.J., TengS.C.A comparison of methylene blue and Lymphazurin in breast cancer sentinel node mapping.Am J Surg2002; 184: 341–5.
19.
GolshanM., NakhlisF.Can methylene blue only be used in sentinel lymph node biopsy for breast cancer?Breast J2006; 12: 428–30.
20.
MasannatY., ShenoyH., SpeirsV.Properties and characteristics of the dyes injected to assist axillary sentinel node localization in breast surgery.Eur J Surg Oncol2006; 32: 381–4.
21.
MasannatY., ShenoyH., SpeirsV.Properties and characteristics of the dyes injected to assist axillary sentinel node localization in breast surgery.Eur J Surg Oncol2006; 32: 381–4.
22.
KellerB., YawalkarN., PichlerC.Hypersensitivity reaction against patent blue dye during sentinel node removal in three melanoma patients.Am J Surg2007; 193: 122–4.
23.
KwokE.S., HowesD.Use of methylene blue in sepsis: a systemic review.J Intensive Care Med2006; 21: 359–63.
24.
SalhabM., SarakbiW., MokbelK.Skin and fat necrosis of the breast following methylene blue injection for sentinel node biopsy in a patient with breast cancer.International Seminars in Surgical Oncology2005; 2: 26.
25.
LeongS.P., DoneganE., HeffernonW.Adverse reactions to isosulfan blue during selective sentinel lymph node dissection in melanoma.Ann Surg Oncol2000; 7: 361–6.
26.
CimminoV.M., BrownA.C., SzocikJ.F.Allergic reactions to isosulfan blue during sentinel node biopsy—a common event.Surgery2001; 130: 439–42.
27.
WrightsonW.R., WongS.L., EdwardsM.J.Complications associated with sentinel lymph node biopsy for melanoma.Ann Surg Oncol2003; 10: 676–80.