We report a case of a translocated intrauterine device (IUD) embedded within the colon wall. Endoscopic tattooing and laparoscopy was used to identify the colonic site and facilitate extraction by colonic resection. A review of the literature and discussion of laparoscopic management of this complication is presented.
Get full access to this article
View all access options for this article.
References
1.
ChengD.The intrauterine device: Still misunderstood after all these years.South Med J2000; 93: 859–64.
2.
DeanG., GoldbergA.The intrauterine contraceptive device.2004. Available at http://www.uptodate.com.
3.
AnderssonK., Ryde-BlomquistE., LindellK.Perforation with intrauterine devices: report from a Swedish survey.Contraception1998; 57: 251–5.
ThomallaJ.V.Perforation of urinary bladder by intrauterine device.Urology1986; 27: 260–4.
6.
SarkarP.Translocation of a copper 7 intra-uterine contraceptive device with subsequent penetration of the caecum: case report and review.Br J Fam Plann2000; 26: 161.
7.
BrowningJ.J., BigriggM.A.Recovery of an intrauterine contraceptive device from the sigmoid colon, 3 case reports.Br J Obstet Gynaecol1988; 95: 530–2.
8.
OhanaE., SheinerE., LeronE.Appendix perforation by an intrauterine contraceptive device.Eur J Obstet Gynecol Reprod Biol2000; 88: 129–31.
9.
ChenC., HsuT., WangW.Ileal penetration by a multiload Cu 375 intrauterine contraceptive device.Contraception1998; 58: 295–304.
10.
PirwanyI., BoddyK.Colocolonic fistula caused by a previously inserted intrauterine device.Contraception1997; 56: 337–9.
11.
SmithP.A., EllisC.J., SparksR.A.Deaths associated with intrauterine contraceptive devices in the United Kindom between 1973 and 1983.BMJ1983; 287: 1537–8.
12.
WynterS., DacostaV., FredrickJ., WynterH.Lapraroscopic retrieval of perforated intrauterine devices at University Hospital, Jamaica.J Am Assoc Gynecol Laparosc2002; 9: 380–3.
13.
SilvaP., LarsonK.Laparoscopic removal of a perforated intrauterine device from the perirectal fat.JSLS2000; 4: 159–62.
14.
IncebozU., CaglarH.Migration of an intrauterine contraceptive device to the sigmoid colon: a case report.Eur J Contracept Reprod Health Care2003; 8: 229–32.
15.
GungorM., SonmezerM., AtabekogluC., OrtacF.Laparoscopic management of a translocated intrauterine device perorating the bowel.J Am Assoc Gynecol Laparosc2003; 10: 539–41.
16.
SenagoreA., DuepreeH., DelaneyC.Results of a standardized technique and postoperative care plan for laparoscopic sigmoid colectomy: a 30-month experience.Dis Col Rect2003; 46: 503–9.