We present a short case of a total endovascular repair of a ruptured thoracic pseudoaneurysm after previous coarctation aortic conduit bypass surgery. A 67-year-old man with two previous coarctation repairs many years ago was admitted with chest pain, dyspnea, and hemoptysis. Computed tomography showed a rupture in the distal anastomosis of the thoracic extra-anatomic graft. Successful treatment was achieved by placement of an endovascular stent graft between the old graft and the native aorta and with a vascular plug occlusion of the native aorta.
BrownM.L., BurkhartH.M., ConnollyH.M., DearaniJ.A., HaglerD.J., SchaffH.V.Late outcomes of reintervention on the descending aorta after repair of aortic coarctation. Circulation.2010; 122(Suppl 11): S81–S84.
2.
KnyshovG.V., SitarL.L., GlagolaM.D., AtamanyukM.Y.Aortic aneurysms at the site of the repair of coarctation of the aorta: a review of 48 patients. Ann Thorac Surg.1996; 61: 935–939.
3.
BottaL., RussoV., OppidoG.Role of endovascular repair in the management of late pseudo-aneurysms following open surgery for aortic coarctation. Eur J Cardiothorac Surg.2009; 36: 670–674.
4.
MarcheixB., LamarcheY., PerraultP.Endovascular management of pseudo-aneurysms after previous surgical repair of congenital aortic coarctation. Eur J Cardiothorac Surg.2007; 31: 1004–1007.
5.
MidullaM., DehaeneA., GodartF.TEVAR in patients with late complications of aortic coarctation repair. J Endovasc Ther.2008; 15: 552–557.
6.
CazavetA., Blot SouletieN., RousseauH., LeobonB.Endovascular repair of a late pseudoaneurysm after an extra-anatomic bypass for aortic coarctation. Eur J Cardiothorac Surg.2013; 44: 389.