Abstract
Objective
This study assessed a resin modified glass ionomer bonding system,
Design
Ex vivo study. Twenty extracted premolar teeth in each group were bonded as follows: (i) Group 1 Control (Transbond); (ii) Group 2 Fuji ortho L.C. without an etch procedure/wet enamel surface; (iii) Group 3 Fuji ortho L.C. without an etch procedure/dry enamel surface; (iv) Group 4 Fuji ortho L.C. using a conventional acid etch technique.
Outcome
Shear bond strength, site of bond failure and adhesive remnant index.
Results
Brackets bonded as recommended by the manufacturer (Group 2) have significantly (p < 0•001) lower bond strengths compared with the control (Group 1). Bonding with an etch technique (Group 4) will significantly (p < 0•001) increase the bond strength compared with the other Fuji groups. All the Fuji groups tended to fail at the enamel/resin interface with lower ARI scores compared with the control.
Conclusion
The lower bond strength of Fuji ortho L.C. would limit its use as a routine bonding agent. When bonded with an acid etch technique, the bond strength may be sufficient for low loading situations such as the upper anterior teeth.