FerrettiG, GussoniM, Di PramperoPE, CerretelliP. Effects of exercise on maximal instantaneous muscular power of humans. J Appl Physiol, 1987; 62:2288–2294.
2.
CooperCB, StorerTW. Exercise testing and interpretation: A practical approach. UK: Cambridge University Press, 2001.
3.
CooperKH. A means of assessing maximal oxygen uptake. JAMA, 1968; 203:201–204.
4.
MitchellH, SprouleBJ, ChapmanCB. The physiological meaning of the maximal oxygen intake test. J Clin Invest, 1958; 37:538–547.
5.
StevensD, ElpernE, SharmaK. Comparison of hallway and treadmill six minute walking test. Am J Respir Crit Care Med, 1999; 160:1540–1543.
6.
ATS Committee on Proficiency Standards for Clinical Pulmonary Function Laboratories. ATS statement: Guidelines for the six-minute walk test. Am J Respir Crit Care Med, 2002; 166:111–117
7.
LiAM, YinJ, YuC, TsangT, SoAK, WongE, ChanD, HonE, SungR. The six-minute walk test in healthy children: Reliability and validity. Eur Respir J, 2005; 25:1057–1060.
8.
GulmansV, Van VeldhovenN, De MeerK, HeldersP. The six-minute walking test in children with cystic fibrosis: Reliability and validity. Pediatr Pulmonol J, 1996; 22:85–89.
9.
EnrightPL, Mc BurnieMA, BitterV, TracyRP, Mc NamaraR, ArnoldA, NewmanAB. Il test del cammino dei 6 minuti. Una misura rapida dello stato funzionale negli adulti anziani. CHEST Edizione Italiana, 2003; 4:28–39.
10.
TroostersT, GosselinkR, DecramerM. Six minute walking distance in healthy elderly subjects. Eur Respir J, 1999; 14:270–274.
11.
SolwayS, BrooksD, LacasseY, ThomasS. A qualitative systemic overview of the measurement properties of functional walk tests used in the cardiorespiratory. Chest, 2001; 119:256–270.
12.
BruceRA, LovejoyFW, PearsonR, YuP, BrothersGB, VelasquezT. Normal respiratory and circulatory pathways of adaptation in exercise. J Clin Invest, 1949; 28:1423–1430.
13.
BalkeB, WareRW. An experimental study of physical fitness of Air Force personnel. U.S. Armed Forces Med J, 1959; 10:675–688.
14.
GiansantiD, MorelliS, MaccioniG, GiordanoA, TamburellaF, MolinariM, SilvestriS, CalabreseS, MacellariV, GrigioniM. Design and construction of a portable kit for the assessment of gait parameters in daily-rehabilitation. Roma: Istituto Superiore di Sanità; 2010. (Rapporti ISTISAN 10/16).
15.
GiansantiD, MorelliS, MaccioniG, GrigioniM. Portable kit for the assessment of gait parameters in daily telerehabilitation. Telemed J E Health, 2013; 19:224–232.
16.
GiansantiD, MacellariV, MaccioniG. Telemonitoring and telerehabilitation of patients with Parkinson's disease: Health technology assessment of a novel wearable step counter. Telemed J E Health, 2008; 14:76–83.
17.
MaccioniG, MacellariV, GiansantiD. Design and construction of step counters for disable people: Preliminary experience at the Italian Institute of Health. Conf Proc IEEE Eng Med Biol Soc, 2007; 4927–4929.
18.
MaccioniG, MorelliS, GrigioniM, CeccarelliG, VulloV, D' EttorreG, BernardiM, D'AlessioA, GiorgioD, MuscaritoliM, GiansantiD. Portable kit for the functional assessment during the walking test [in Italian]. 13th Congress Siamoc, Bellaria, 2012.