Abstract
Abstract
Background:
Catheter-
Methods:
Prospective surveillance of CA-BSI (defined as bacteremia with no extravascular source identified) is performed in all intensive care units (ICUs) at our institution and reported as the rate per 1,000 catheter-days. In January 2006, we initiated cultures of all catheter tips to evaluate for CR-BSI (defined as a catheter tip culture with >15 colony-forming units of the same microorganism(s) found in the blood culture) in the surgical, trauma-burn, and medical ICUs.
Results:
The CA-BSI rate across all ICUs for the 24-mo study period was 1.4/1,000 catheter-days. The CR-BSI rate was 0.4/1,000 catheter days, for a rate difference of 1.0 infections/1,000 catheter-days (p < 0.001 vs. CA-BSI). The pathogens identified in CA-BSI included many organisms that are not associated with catheter-related BSIs.
Conclusions:
The CR-BSI rate is significantly lower than the CA-BSI rate. The organisms identified in CA-BSI surveillance often are not common in catheter-related infections. Reporting CR-BSI thus is a more accurate measure of complications of central venous catheter use, and this rate may be more sensitive to catheter-specific interventions designed to reduce rates of BSI in the ICU.
Get full access to this article
View all access options for this article.
