Objective:
The aim of this study was to investigate and compare the clinical, microbial, and inflammatory effects of a diode laser as an adjunct to scaling and root planing (SRP) versus SRP alone for the treatment of generalized aggressive periodontitis (GAgP).
Methods:
Using a split-mouth design, 31 patients with GAgP were enrolled in the study. The maxillary right and left quadrants were randomly assigned to SRP+diode laser or SRP alone. Patients were examined on a regular basis for clinical, microbiological, and inflammatory mediator changes over a 1-year period. Clinical attachment level (CAL) was the primary outcome variable chosen. In addition, subgingival biofilm samples and gingival crevicular fluid (GCF) inflammatory mediators were analyzed at each follow-up session.
Results:
Compared to baseline, both treatments demonstrated an improvement in periodontal parameters at 1 year. However, SRP+diode laser produced a significant improvement in probing depth (PD; 2.56 ± 0.44 vs. 3.36 ± 0.51 mm, p < 0.05) and CAL (3.47 ± 0.25 vs. 4.11 ± 0.26 mm, p < 0.05) values compared to SRP alone. Similarly, in the SRP+diode laser group, the bacteria of orange complex group were significantly reduced at 30 and 60 days compared to SRP alone. Moreover, SRP+diode laser determined a reduction in mean GCF level of interleukin (IL)-1β and IL-1β/IL-10 ratio at 15 and 30 days compared to SRP alone (p < 0.05).
Conclusions:
At 1 year, SRP+diode laser yielded a significant reduction in some clinical parameters, while microbial and inflammatory mediator changes were not significantly reduced compared to SRP alone.
Supplementary Material
Please find the following supplemental material available below.
For Open Access articles published under a Creative Commons License, all supplemental material carries the same license as the article it is associated with.
For non-Open Access articles published, all supplemental material carries a non-exclusive license, and permission requests for re-use of supplemental material or any part of supplemental material shall be sent directly to the copyright owner as specified in the copyright notice associated with the article.
0.00 MB
0.04 MB