Background:
As a relatively new approach, popularity of pneumovesicoscopic surgery is increasing, but slower than expected due to complex nature of the procedure with efforts to overcome the difficult steps of the procedure. Bladder fixation is one of the crucial steps of the procedure. In this study, we present a novel and simple T-bar technique to overcome this difficulty.
Methods:
We retrospectively evaluated 24 consecutive patients (39 ureters) who underwent pneumovesicoscopic surgery with fixation of the bladder wall between December 2017 and September 2019.
Results:
Fixation by transabdominal suture (TS) was performed in 3 patients, while fixation by thread loops with needle in 3 and T-bar device in 18. Tearing of the bladder wall was encountered in 2 patients in TS, in 2 patients with thread loop groups, but none in the T-bar group. Conversion to open surgery was necessary in 3 patients in the T-bar group, but only 1 was related with the fixation technique.
Conclusions:
T-bar technique is an inexpensive and simple solution providing stable and reliable bladder wall and working port fixation during pneumovesicoscopy.
Get full access to this article
View all access options for this article.
References
Supplementary Material
Please find the following supplemental material available below.
For Open Access articles published under a Creative Commons License, all supplemental material carries the same license as the article it is associated with.
For non-Open Access articles published, all supplemental material carries a non-exclusive license, and permission requests for re-use of supplemental material or any part of supplemental material shall be sent directly to the copyright owner as specified in the copyright notice associated with the article.