Abstract
Abstract
Background:
Common bile duct (CBD) injury is a serious complication of laparoscopic and open cholecystectomy. Early identification and minimally invasive repair, when possible, can prevent much of the morbidity associated with this injury.
Materials and Methods:
A 36-year-old woman referred in the immediate perioperative period for CBD injury at the time of laparoscopic cholecystectomy. We present a case of early robot-assisted repair of a Strasberg class E1 bile duct injury with Roux-en-Y hepaticojejunostomy.
Results:
Total console time of 4 hours with minimal blood loss and no requirement for transfusion with length of stay of 3 days. No intra- or perioperative complications of the surgery were noted.
Conclusion:
The degrees of freedom and stability of the robotic platform were instrumental during several key steps, including exposure of the hepatic hilum, positioning of the Roux limb, and suturing of the CBD. Successful minimally invasive repair of this patient's CBD injury minimized the morbidity of the index operation, blood loss, hospital length of stay, and potential legal consequences.
Get full access to this article
View all access options for this article.
References
Supplementary Material
Please find the following supplemental material available below.
For Open Access articles published under a Creative Commons License, all supplemental material carries the same license as the article it is associated with.
For non-Open Access articles published, all supplemental material carries a non-exclusive license, and permission requests for re-use of supplemental material or any part of supplemental material shall be sent directly to the copyright owner as specified in the copyright notice associated with the article.