Abstract
Background:
Targeting drugs to the olfactory region in the nasal cavity can bypass the restrictive blood
Methods:
In this study, three anatomically accurate human nasal cavities were reconstructed in silico and deposition of microparticles under nebulization and bi-directional airflow conditions was simulated. Microparticle deposition data were analyzed to gain insight into the effect of particle size and nasal geometry.
Results:
Maximum olfactory deposition was observed with particles in the size range of 8 to 12 μm under nebulization and 14 to 18 μm under bi-directional airflow condition. Geometric differences between subjects were shown to significantly impact overall and regional particle deposition and introduced inter-subject variability. Significant intra-subject variability in microparticle deposition was also observed in the bi-directional delivery cases.
Conclusions:
The data from this study suggest that tailoring particle size, combined with a delivery protocol, may provide a unique and pragmatic way to target drugs to the olfactory region. Differences in nasal anatomy among humans can cause variability in particle deposition and need to be considered in any future applications.
Get full access to this article
View all access options for this article.
References
Supplementary Material
Please find the following supplemental material available below.
For Open Access articles published under a Creative Commons License, all supplemental material carries the same license as the article it is associated with.
For non-Open Access articles published, all supplemental material carries a non-exclusive license, and permission requests for re-use of supplemental material or any part of supplemental material shall be sent directly to the copyright owner as specified in the copyright notice associated with the article.