Abstract
ABSTRACT
To investigate the potential use of aerosol dispersion (AD) and the skewness (SK) of expired aerosol boluses in detecting and characterizing lung injury, AD and SK were computed in a model of inhomogeneous ventilation. The lung was represented as two parallel compartments with volumes V1 and V2 and ventilatory time constants τ1 and τ2. Within a compartment, inspired aerosol was assumed to disperse as a Gaussian function of inspired volume. Expired aerosol concentration was computed by the complete mixing of expirate from the compartments. AD was defined as the square root of the difference of the variances of inspired and expired boluses with the coefficient of dispersion (CD) = AD/VP. For V1 = V2 and τ2 > τ1, CD and SK
The results suggest that: 1) CD and SK are markers of parallel inhomogeneity in lung ventilation, 2) CD and SK may be more sensitive to lung injury when measured at higher flow, and 3) SK may be particularly sensitive to a small region of injured lung.