Abstract
Objective:
The objective of this study was to investigate the feasibility of 1-d 68Ga-DOTA-FAPI-04 and 18F-FDG (2-deoxy-2[18F]fluoro-
Materials and Methods:
Fifty-two patients who underwent 18F-FDG and 68Ga-DOTA-FAPI-04 PET/CT were divided into 1- and 2-d groups. Image acquisition, injection time, and total waiting time were compared. For the 68Ga-DOTA-FAPI-04 PET/CT scans, low-dose CT scans and low injection dosages were employed, and total radiation dose was assessed for both protocols. The comparative analysis included assessment of patient-based detection rates and lesion-based diagnostic efficacy.
Results:
The total waiting time was significantly shorter in the 1-d group than in the 2-d group (p = 0.000). The radiation doses stemming from internal radiation and external radiation between the groups showed no differences (p = 0.151 vs. 0.716). In the patient-based analysis, the detection rates for local recurrence, peritoneal, lymph node, and other metastases were not significantly different in both protocols (p ∈ [0.351, 1.000]). For the lesion-based analysis, no differences were noted in terms of sensitivity, specificity, positive predictive value, negative predictive value, and accuracy (p ∈ [0.371, 1.000]).
Conclusions:
The 1-d PET/CT protocol reduced waiting time and exhibited equivalent detectability compared with the 2-d protocol, suggesting its clinical value.
Get full access to this article
View all access options for this article.