Abstract
Background
Blood transfusion rates after total knee arthroplasty (TKA) in patients without hemophilia have diminished with the use of a standardized multimodal blood loss prevention method (MBLPM) that includes intra-articular tranexamic acid (TXA) (MBLPM-TXA). However, the topic has not been addressed in people with hemophilia.
Questions/Purposes
Our aim was to investigate whether the MBLPM-TXA prevents blood loss in patients with hemophilia A who undergo TKA, thereby decreasing the need for post-operative blood transfusion.
Methods
This retrospective case–control comparative study involved 30 TKA patients who had a severe degree of hemophilia A without inhibitions: one group treated with the MBLPM-TXA (n = 15) and a second group treated without it (n = 15). In all cases, the pre-operative hemoglobin level was greater than 13 g/dL.
Results
The MBLPM-TXA group had a transfusion rate of zero, whereas 46.6% of the patients (seven of 15) in the non–MBLPM-TXA group needed transfusion.
Conclusion
This retrospective case–control study showed that the use of an MBLPM-TXA in patients with hemophilia A who underwent TKA was effective in reducing rates of transfusion. We recommend its use.
Keywords
Get full access to this article
View all access options for this article.