Abstract
Importance
Hyaluronic acid filler can be safely used as a soft-tissue filler for correction of infraorbital hollowing. It has a high overall patient satisfaction profile among patients.
Objective
To report safety and patient satisfaction outcomes of Juvéderm Voluma XC for correction of infraorbital hollows.
Design, Setting, and Patients
This was a retrospective observational study performed at a private ambulatory facial plastic and reconstructive surgery practice. Participants were all patients 21 to 85 years old who presented to our practice and underwent Juvéderm Voluma XC treatment for correction of infraorbital hollows as a singular intervention from February 2016 to March 2017.
Interventions
Injection of Juvéderm Voluma XC to the tear trough, nasojugal fold, and/or palpebromalar groove.
Main Outcomes and Measures
Primary outcome measures include the number of recorded short- and long-term adverse events, need for additional treatment, and patient questionnaire FACE-Q scores.
Results
A total of 202 eyes were treated in 101 patients with a mean follow-up of 12 months. Patients were principally female (90 [89%]) with an average age of 54 years (range, 21-85 years). Most patients (99) had Fitzpatrick grade 1 to 4 skin type (98%) and had an infraorbital hollows score of 2 to 4 (89 [88%]). The average initial treatment volume was 1 mL with 18 patients (18%) requiring additional treatment within 3 months. The average time until additional treatment was 35.7 days. Adverse effects include bruising (in 10 [10%], contour irregularities (2 [2%]), swelling (3 [3%]), and Tyndall effect (1 [1%]). Hyaluronidase was required in 3 patients (3%). Forty-one patients completed the FACE-Q Satisfaction With Eyes survey, and 42 patients completed the FACE-Q Satisfaction With Decision survey (41% and 42%). Overall mean (SD) patient satisfaction (based on FACE-Q scores) was 71.1% (27.3) and 65.6% (31.3), respectively.
Conclusions and Relevance
Juvéderm Voluma XC has a high patient satisfaction profile and an acceptable safety profile for the correction of infraorbital hollowing.
Level of Evidence
4.
Get full access to this article
View all access options for this article.
References
Supplementary Material
Please find the following supplemental material available below.
For Open Access articles published under a Creative Commons License, all supplemental material carries the same license as the article it is associated with.
For non-Open Access articles published, all supplemental material carries a non-exclusive license, and permission requests for re-use of supplemental material or any part of supplemental material shall be sent directly to the copyright owner as specified in the copyright notice associated with the article.